Strona 1 - 4800 Express

BitStorm® 4800 ExpressModel 4821-A2Installation GuideDocument No. 4821-A2-GN21-10July 2004

Strona 2

About This Guideiv July 2004 4821-A2-GN21-10Related Product DocumentsDocumentation for the BitStorm 4800 Express IP DSLAM is available on the World Wi

Strona 3

4821-A2-GN21-10 July 2004 1-11InstallationOverviewThe BitStorm® 4800 Express is a stackable IP DSLAM designed for installation in a Central Office (CO

Strona 4 - C July 2004 4821-A2-GN21-10

1. Installation1-2 July 2004 4821-A2-GN21-10PreparationConsider the following before installing the BitStorm 4800 Express IP DSLAM: Installation Si

Strona 5 - CANADA – EMI NOTICE:

1. Installation4821-A2-GN21-10 July 20041-3Cables RequiredTabl e 1 -2 shows all the cables that may be required for your installation.Table 1-2. Cable

Strona 6 - CE Marking

1. Installation1-4 July 2004 4821-A2-GN21-10Unpacking the HardwareHANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES This product is designed to prot

Strona 7 - Contents

1. Installation4821-A2-GN21-10 July 20041-5Table 1-3. Contents of Hardware Kit Shipped with the BitStorm 4800 ExpressAppearance Description QuantityFl

Strona 8 - C Technical Specifications

1. Installation1-6 July 2004 4821-A2-GN21-10Mounting Configurations Three basic installation configurations are available: Rack mount – see Install

Strona 9 - About This Guide

1. Installation4821-A2-GN21-10 July 20041-73. Identify six flat-head screws (for 19-inch racks) or six machine screws (for 23-inch racks) provided wit

Strona 10 - Related Product Documents

1. Installation1-8 July 2004 4821-A2-GN21-10Installing the BitStorm 4800 Express Into a RackTwo types of mounting screws are provided. Use: #10-32

Strona 11 - Installation

1. Installation4821-A2-GN21-10 July 20041-93. Insert and tighten the screws in the top screw positions, then tighten the bottom screws. 04-17526PORT1-

Strona 12 - Preparation

A July 2004 4821-A2-GN21-10Copyright © 2004 Paradyne Corporation.All rights reserved.Printed in U.S.A.NoticeThis publication is protected by federal c

Strona 13 - Cables Required

1. Installation1-10 July 2004 4821-A2-GN21-10Installing the BitStorm 4800 Express on a WallWall mounting requires two wood screws suitable for the w

Strona 14 - Package Contents

1. Installation4821-A2-GN21-10 July 20041-116. Install two wood screws (not provided) at the same height above the floor and 18.75 inches (476.25 mm)

Strona 15 - 02-17325

1. Installation1-12 July 2004 4821-A2-GN21-10Installing the BitStorm 4800 Express on a Shelf or DesktopIf the BitStorm 4800 Express will be placed o

Strona 16 - Mounting Brackets

4821-A2-GN21-10 July 2004 2-12CablingCabling OverviewThe BitStorm 4800 Express has a large variety of possible cabling configurations. This chapter de

Strona 17 - 4821-A2-GN21-10 July 2004

2. Cabling2-2 July 2004 4821-A2-GN21-10DSL PortsThe BitStorm 4800 Express DSL connector supports the tip and ring connections of up to 24 DSL ports

Strona 18 - Procedure

2. Cabling4821-A2-GN21-10 July 20042-36. Secure the cables as required for strain relief.10/100BaseT Uplink (Port 2)Port 2 is the uplink for the DSLAM

Strona 19

2. Cabling2-4 July 2004 4821-A2-GN21-10Management PortPort 1 can be used to connect the BitStorm 4800 Express to a network management system using a

Strona 20

2. Cabling4821-A2-GN21-10 July 20042-5Console PortThe CONSOLE port normally serves as the primary user interface with the BitStorm 4800 Express during

Strona 21 - 17.85 in (453 mm)

2. Cabling2-6 July 2004 4821-A2-GN21-10Connecting a Modem to the Console PortProcedureTo connect a modem to the CONSOLE port:1. Determine and procur

Strona 22

2. Cabling4821-A2-GN21-10 July 20042-7GroundProcedureTo connect the unit to a ground:1. Crimp a ring terminal onto the stripped end of 14 AWG or heavi

Strona 23 - Cabling Overview

4821-A2-GN21-10 July 2004 BSoftware and Firmware License AgreementThe terms and conditions of this License Agreement (the “Agreement”) will apply to t

Strona 24 - DSL Ports

2. Cabling2-8 July 2004 4821-A2-GN21-10Connecting to PowerThe BitStorm 4800 Express can be powered by any AC power source supplying 90–265 VAC at 47

Strona 25 - 10/100BaseT Uplink (Port 2)

4821-A2-GN21-10 July 2004 3-13LEDsLED LocationsThe locations of the System and DSL Port LEDs on the front panel of the BitStorm 4800 Express are shown

Strona 26 - Management Port

3. LEDs3-2 July 2004 4821-A2-GN21-10LED MeaningsWhen power is first applied to the unit, it performs a power-on self-test. When this test is success

Strona 27 - Console Port

4821-A2-GN21-10 July 2004 4-14ConfigurationOverviewThe BitStorm 4800 Express is designed to require minimal configuration before it can be accessed by

Strona 28 - Serial Port

4. Configuration4-2 July 2004 4821-A2-GN21-10Using the CLI A command line interface (CLI) can be used to configure and monitor the unit. The CLI is

Strona 29 - RTS 25-48

4. Configuration4821-A2-GN21-10 July 20044-3Configure Management Inband AddressThe configure management inband address command specifies the IP addres

Strona 30 - Connecting to Power

4. Configuration4-4 July 2004 4821-A2-GN21-10BitStorm 4800 Express Startup ProcedureYou can initialize your BitStorm 4800 Express via a PC or termin

Strona 31 - LED Locations

4. Configuration4821-A2-GN21-10 July 20044-5Startup Procedure for Inband ManagementWith inband management, the BitStorm 4800 Express is managed using

Strona 32 - LED Meanings

4. Configuration4-6 July 2004 4821-A2-GN21-10Using the Web InterfaceTo access the web interface:Procedure1. Open your web browser. (Internet Explore

Strona 33 - Configuration

4. Configuration4821-A2-GN21-10 July 20044-7System / UsersFor security reasons, it is a good idea to change the default password the first time you us

Strona 34 - Using the CLI

C July 2004 4821-A2-GN21-107. The rights granted under this Agreement may not be assigned, sublicensed or otherwise transferred by the Licensee to any

Strona 35

4. Configuration4-8 July 2004 4821-A2-GN21-10Configuration / Management / SNMPSNMP access to the unit is disabled by default. The read-only communit

Strona 36 - Management Modes

4821-A2-GN21-10 July 2004 A-1AConnectors and Pin AssignmentsOverviewThe following sections provide pin assignments for: DSL Ports Connectors on page

Strona 37

A. Connectors and Pin AssignmentsA-2 July 2004 4821-A2-GN21-10DSL Ports ConnectorsThe 50-pin RJ21X Telco connectors labeled DSL Ports 1–24 and (on t

Strona 38 - Using the Web Interface

A. Connectors and Pin Assignments4821-A2-GN21-10 July 2004A-3Port 1 and Port 2 10/100BaseT ConnectorsPort 1 and Port 2 are 8-pin unkeyed modular jacks

Strona 39 - System / Users

A. Connectors and Pin AssignmentsA-4 July 2004 4821-A2-GN21-10Console Port ConnectorThe CONSOLE port connector is a DB9 socket connector that suppor

Strona 40

4821-A2-GN21-10 July 2004 B-1BEquipment List Table B-1. BitStorm 4800 Express Equipment ListDescription Model NumberBitStorm 4800 Express Model 4821-A

Strona 41 - Overview

B. Equipment ListB-2 July 2004 4821-A2-GN21-10

Strona 42 - 02-17151

4821-A2-GN21-10 July 2004 C-1CTechnical SpecificationsTechnical specifications are subject to change without notice. Table C-1. BitStorm 4800 Express

Strona 43 - Signal Pin

C. Technical SpecificationsC-2 July 2004 4821-A2-GN21-10

Strona 44 - Console Port Connector

4821-A2-GN21-10 July 2004 IN-1IndexNumerics10/100BaseT pinouts, A-3AAC power, 2-8Activity LEDs, 3-2administrator, login, 4-4Alarm LED, 3-2audienc

Strona 45 - Equipment List

4821-A2-GN21-10 July 2004 D10. CLASS 1 LASER PRODUCT: This product has provisions for the customer to install a Class 1 laser transciever, which provi

Strona 46 - July 2004 4821-A2-GN21-10

IndexIN-2 July 2004 4821-A2-GN21-10EthernetLEDs, 3-2Ffasteners provided, 1-5feature numbers, B-1features, 1-1feet, 1-12front panel, 3-1, A-1illu

Strona 47 - Technical Specifications

Index4821-A2-GN21-10 July 2004IN-3POTS splittercabling, 2-2pin assignments, A-2port description, 1-3power, C-1connecting to, 2-8consumption, C-1

Strona 48 - C. Technical Specifications

IndexIN-4 July 2004 4821-A2-GN21-10

Strona 49

E July 2004 4821-A2-GN21-10Notices to Users of the Canadian Telephone NetworkNOTICE: This equipment meets the applicable Industry Canada Terminal Equi

Strona 50

4821-A2-GN21-10 July 2004 iContentsAbout This Guide Document Purpose and Intended Audience . . . . . . . . . . . . . . . . . . . . iii Document Su

Strona 51

Contentsii July 2004 4821-A2-GN21-104 Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 52 - July 2004 4821-A2-GN21-10

4821-A2-GN21-10 July 2004 iiiAbout This GuideDocument Purpose and Intended AudienceThis document is written for technicians who install the BitStorm®