3. Commands
4821-A2-GB21-00 July 2004 3-27
Configure Interface DSL Profile Alarm Downstream Error Seconds
Configure Interface DSL Profile Alarm Downstream Increasing Rate
Configure interface dsl-profile-alarm downstream-es {es} {profile_name}
Minimum Access Level: Administrator
The configure interface dsl-profile-alarm downstream-es command modifies the downstream
errored seconds required to generate an alarm.
profile_name – Identifies the ADSL Alarm profile to be modified.
es - SNMP trap is sent if the number of errored seconds events in a 15-minute interval meets or exceeds
the selected value (0–900 seconds, where 0 disables the messages).
Example:
PDYN# configure interface dsl-profile-alarm downstream-es 500 adsl_alarm_profile1
Configure interface dsl-profile-alarm downstream-ir {ir} {profile_name}
Minimum Access Level: Administrator
The configure interface dsl-profile-alarm downstream-ir command modifies the downstream
increasing rate to generate an alarm.
profile_name – Identifies the ADSL Alarm profile to be modified.
ir - SNMP rate change trap is sent if the current rate is greater than or equal to the previous rate plus this
threshold (065535 kbps, where 0 disables the messages).
Example:
PDYN# configure interface dsl-profile-alarm downstream-ir 50000 adsl_alarm_profile1